You are installing networking wiring for a new Ethernet network at your company’s main office building. The project specifications call for Category 5 UTP network cabling and RJ45 wall jacks. Near the end of the project, you run out of wire before the last few runs are complete. You have a spool of Category 3 network cable in storage. Upon investigation, it appears very similar to Category 5 wiring. Should you substitute Category 3 cabling for Category 5 cabling to finish the project? |
D) No, Category 5 cabling has more twists per inch than Category 3 cabling to reduce crosstalk and support higher data rates. |
Which of the following cable types often includes a solid plastic core? |
B) Cat 6 |
You are adding new wires in your building for some new offices. The building has a false ceiling that holds the lights. You would like to run your Ethernet cables in this area. Which type of cable must you use? |
C) Plenum |
Which of the following connectors is used with Ethernet 10BaseT networks? |
D) RJ45 |
In which of the following situations might you use an RJ11 connector? |
B) You want to connect your computer to the Internet with a dialup connection. |
When would you typically use an RJ11 connector? |
F) When connecting a phone to a phone line. |
Which of the following connector types would you most likely use to connect to a T1 WAN service? |
B) RJ48 |
Which of the following are characteristics of coaxial network cable? (Choose three.) |
B) It uses two concentric metallic conductors. C) It has a conductor made from copper in the center of the cable. G) The ends of the cable must be terminated. |
Which of the following cable classifications are typically used for cable and satellite networking with coaxial cables? (Select two.) |
A) RG-6 D) RG-59 |
You have a small home network connected to the Internet using an RG6 cable. You need to move the router connecting the network to the Internet, but can’t find any RG6 cable. Which cable types could you use instead? |
A) RG-59 |
Of the following cables, which offer the best protection against EMI? |
A) RG-6 |
You have just signed up for a broadband home Internet service that uses coaxial cable. Which connector type will you most likely use? |
F) F-type |
Ftype connectors are typically used with cables using which of the following standards? (Select two.) |
B) RG-59 D) RG-6 |
You are working with an older 10Base2 Ethernet network. |
D) BNC |
Which of the following forms of optical fiber would usually be used to connect two buildings across campus from each other, which are several kilometers apart? |
A) Single mode |
Which of the following are advantages of using fiber optic cabling for a network, as opposed to other types of cabling? (Select two.) |
A) Greater cable distances without a repeater B) Immunity to electromagnetic interference |
Which of the following is true about single mode fiber optic network cabling? |
B) The central core is smaller than that of multimode fiber optic cabling. |
Of the following cables, which offer the best protection against EMI? |
C) Single mode fiber optic |
Which of the following connectors usually require polishing as part of the assembly process? |
D) SC E) ST |
Which of the following are characteristics of an LC fiber optic connector? (Choose two.) |
C) They are half the size of standard connectors. F) They use a housing and latch system similar to an RJ45 UTP connector. |
Which of the following are characteristics of an MTRJ fiber optic connector? (Select two.) |
D) They use metal guide pins to ensure accurate alignment F) They can be used with multimode fiber optic cables. |
Which of the following connectors is used with fiber optic cables and connects using a twisting |
B) ST |
Which of the following connectors are used with fiber optic cables and include both cables in a |
A) MT-RJ D) LC |
You are building network cables and attaching RJ45 connectors to each end. Which tool do you |
A) Crimping tool |
What tool should you use to extend network services beyond the demarc? |
C) Punchdown tool |
You are making Ethernet drop cables using Cat5e cable and RJ45 connectors. You need to |
C) Cable stripper |
You are working with 25 pair wires and 66 blocks. You have pushed the wires onto the 66 |
B) Punchdown tool |
Which of the following connector types are used with UTP cables? (Select two.) |
A) RJ45 C) RJ11 |
Which of the following describes the point where the service provider’s responsibility ends and |
A) Demarc |
You have a network that occupies all three floors of a building. The WAN service provider has |
A) Vertical cross connect |
You have a network that occupies the top floor of a three story building. The WAN service |
A) Demarc extension |
You have a network that occupies all three floors of a building. The WAN service provider has |
C) Horizontal cross connect D) 25 pair |
You have a network that occupies both floors of a building. The WAN service provider has |
C) IDF |
Which of the following is used to terminate individual wires from a 25 pair or 100 pair cable |
B) Patch panel |
You want to use the T568B standard for adding connectors to your Cat5 cable. Starting with pin |
B) White/orange, orange, white/green, blue, white/blue, green, white/brown, brown |
Which of the following methods would you use to create a crossover cable? |
C) Use the T568A standard on one connector, and the T568B standard on the other connector. |
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization’s IT policy |
1) White with green stripe (2nd one) 2) Solid green (5th one) 3) White with orange stripe (1st one) 4) Solid blue (4th one) 5) White with blue stripe (7th one) 6) Solid orange (8th one) 7) White with brown stripe (6th one) 8) Solid brown (3rd one) |
You need to replace a fiber optic cable that is connecting two switches together. You inspect |
D) Angled Physical Contact Polish |
Which type of polish grade uses greencolored connectors to help prevent using the wrong connector type? |
C) Angled Physical Contact |
Consider the 850 nm multimode fiber optic cable shown below. How much loss can you expect |
D) -1.2 dB |
You are building a new network for a small startup financial services company. Security is |
C) No, you shouldn’t use multimode patch cables with single mode GBIC modules. |
You are building a new network for a small startup financial services company. Security is |
A) No, you should purchase patch cables that use MT-RJ connectors. |
While viewing the status of the interfaces on a Cisco switch, you see an abnormally large |
C) A strong EMI emitter near the cable run connected to that interface. |
While viewing the status of the interfaces on a Cisco switch, you see an abnormally large number of oversized Ethernet frames being received on one interface. This interface is |
B) The workstation’s network board is jabbering. |
testout ch2
Share This
Unfinished tasks keep piling up?
Let us complete them for you. Quickly and professionally.
Check Price